Display Description Cause/Corrective Action
Ed04**
Locked Rotor Error Motor does not reach speed at startup. Power down, verify motor
mounting and look for obstructions, power up and try again.
Ed05**
IGBT Overcurrent Error The drive detects an overcurrent shunt condition. Power down
machine for a minimum of two minutes, verify the motor is not
shorted phase to phase or phase to ground. Power up and try
again. If problem persists, replace drive.
Ed06**
Thermal Error The control detects a high IPM temperature. Power down, verify
convection around drive heat sink, power up and try again.
Ed07**
No Setup Error The drive receives movement commands without receiving a set-
up packet. Power down, power up and try again.
Ed08**
Max Over Current Error The drive detects motor output overcurrent condition. Power
down, power up and try again.
Ed09**
Current Sensor Error The drive detects a current sensor is not operating properly at
startup. Power down, power up and try again. If problem persists,
replace drive.
*To clear the decimal point on display, press the START (enter) keypad 3 times in succession (within 5 seconds).
**Design 2 and 3 models only.
Table 17
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
65 Part No. F8238101ENR11