PAGE127
7 EMERGENCY COMMANDS.
While using the emergency controls, a qualified operator, who must always be present on the ground,
assumes responsibility for moving the machine and the operator on board using the emergency modes
described below.
The operator using the emergency controls must always check that the machine movements take
place in accordance with the commands activated. In the event that non-controlled movements are
activated, proceed directly with the emergency commands using the manual pump.
Contact the authorized service centre.
7.1.1 Emergency recovery of the incapacitated operator.
In the event that the operator on the platform is unable to return to the ground using the platform
controls, a qualified operator in possession of the master key (for machines destined for AUSTRALIA and
NEW ZEALAND the key is always present on the selector key), can activate the emergency controls of the
ground control station.
To use the ground control station:
- Turn the key (1) to the GROUND CONTROLS position (purple box);
- Activate the power supply (electrical or thermal, depending on the type of machine) using the
selector (2);
- Activate the controls of the extensible structure (8-9-10-11-12) as per their description in the
GROUND CONTROL UNIT chapter.
While using the ground controls described in this procedure, all safety functions are active