PAGE136
- Activate the emergency button on the remote control (or radio control), and check that the
platform control console and the heat engine (EVO, ETS versions) turn off. Release the emergency
button at the end of this test.
- Activate the emergency button of the ground control station, and check that the machine is
completely off and that no function is allowed. Release the emergency button at the end of this
test.
- Activate the horn and check its operation.
- Verify that each command stops when the command is released.
- Using the ground control station, check that all the controls are functioning and conform to their
operation.
- Check the correct operation of the manual emergency lowering device using a hand pump.
- Check, when used as a platform, that with the work platform correctly interlocked, the special
warning light on the console signals the "WORK PLATFORM" mode.
- Check, when used as a winch (optional), that with the winch correctly interlocked, the indicator
light on the console signals the "WINCH" mode.