Operating manual ALPHASEAPILOT MFC Issue 1.1 Page 75 of 84
ALPHASEAPILOT MFC
2.43 (iv) To Select the Isolated Input Steering Mode:-
a) Simultaneously press the “CANCEL” and “CONFIRM” keys for 5 seconds until the Set
Up Menu is displayed with a black cursor highlighting the Set Up parameter currently
selected.
b) Rotate the Autopilot Set Course Control to move the cursor to parameter number 62
(NORM/HSC LATCH/JOG).
c) Use the rotary (+/-) illum. control to select as required.
2.43 (v) To Calibrate Isolated Input Steering Modes against Speed:-
Refer to Adaptive Mode Calibration Section 2.29.