Spectrum Analyzer 2-16 EMF Measurement (Option 444)
Spectrum Analyzer MG PN: 10580-00349 Rev. H 2-21
2-16 EMF Measurement (Option 444)
Required Equipment
EMF measurements are available in the Spectrum Analyzer mode only when Option 444 is
installed. The option requires an isotropic antenna, at a frequency range that is within
specification of the instrument. Refer to the isotropic antenna and spectrum analyzer
Technical Data Sheets.
Procedure
1. Press the Shift key, then the Mode (9) key to open the Mode Selector dialog box. Use the
Up or Down arrow keys to highlight the Spectrum Analyzer measurement mode and
press Enter.
2. Press the Shift key followed by the Measure (4) key.
3. To access EMF Measurement, press the Power and Bandwidth submenu key, then EMF
Measurement.
Chapter 9, “EMF (Option 444)” provides connection instructions for the antenna and detailed
descriptions of the EMF Measurement menu and submenus.