CS175-275-575-875 Installation Guide 81
6
On: the zone type is included in the group shunt.
7
On: the zone type is force armable.
8
On: the zone type is entry guard.
Segment 3 1
On: enables fast loop response (50 msec). Off= 500 msec.
2
On: enables double end of line tamper zone. This is generally
used for tampers on wireless zones.
3
On: enables trouble reporting zone. (Day zone and Fire zones)
4
Reserved
5
On: enables dialer delay zone. See Location 28 on page 64 for
more information.
6
On: zone type allows swinger shutdown. See
Location 48
on
page 69 for more information.
7
On: enables restore reporting.
8
On: enables listen-in. See
Location 29
on page 64 for more
information.
Segment 4 1
On: enables zone activity monitor. See
Location 52
on page 71
for more information.
2
“B” alarm zone
3
Final set door
4
Roller shutter zone
5
Double knock
6-8
Reserved
Segment 5
Reserved
"
Both maintened and pulsed keyswitches can be configured. By default, a keyswitch is
maintained. Change segment 3, bit 7 (enable restore reporting) for a pulsed keyswitch.
The information in the following locations is configured in the same way as locations 127,
128, 129 and 130 for zone type 1.The following table contains the locations for phone
number zone groups 1 to 20.
Description 1 2 3 4 5 6 7 8 9 10
SIA
127 131 135 139
143
147 151 155 159 163
4/2 alarm
128 132 136 140
144
148 152 156 160 164
4/2 restore
129 133 137 141
145
149 153 157 161 165
Characteristics
130 134 138 142
146
150 154 158 162 166
Description 11 12 13 14 15 16 17 18 19 20
SIA
167 171 175 179
183
187 191 195 199 203
4/2 alarm
168 172 176 180
184
188 192 196 200 204