11.4 General adjustment
a Set the hold open time with the potentiometer on the control unit.
b Adjust the opening speed (OPSP). Turning clockwise increases the speed.
c Adjust the closing speed (CLSP). Turning counter-clockwise decreases the speed.
See the Guide for installers of Powered Pedestrian Swing Doors, Product Risk Assessment
document PRA-0006, for calculation of speed.
d Connect the required activation units.
e Check that the installation complies with Installation and adjustments on page 63.
1005088-en-22.0Issue 2021-02-2452