14 Advanced settings
14.1 Learn with advanced setting of back- and latch-check
See the prerequisites for performing a learn under the heading Auto-learn automatically sets
back and latch check (recommended) on page 51.
a Push the button once or twice as for auto-setting.
b Stop the door at required back-check.
c The door reverts towards closed position.
d Remove the stop.
e Stop the door at required latch-check.
f The door reverts to learn the fully open position.
g Remove the stop.
h The door reverts to closed position.
14.2 Revert to default values for back- and latch-check" (Level 1)
a Disconnect batteries if any.
b Disconnect the mains.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the mains.
e Watch the ERROR LED.
3 s
f Release the LEARN BUTTON after 1 flash (LED is out).
g The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to default values.
h Disconnect the mains.
i Next time the mains is connected, a new learn is needed to be run, and the operator will use
the default values.