EasyManuals Logo

Assa Abloy SW100 User Manual

Assa Abloy SW100
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
14 Advanced settings
14.1 Learn with advanced setting of back- and latch-check
See the prerequisites for performing a learn under the heading Auto-learn automatically sets
back and latch check (recommended) on page 51.
a Push the button once or twice as for auto-setting.
b Stop the door at required back-check.
c The door reverts towards closed position.
d Remove the stop.
e Stop the door at required latch-check.
f The door reverts to learn the fully open position.
g Remove the stop.
h The door reverts to closed position.
14.2 Revert to default values for back- and latch-check" (Level 1)
a Disconnect batteries if any.
b Disconnect the mains.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the mains.
e Watch the ERROR LED.
3 s
f Release the LEARN BUTTON after 1 flash (LED is out).
g The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to default values.
h Disconnect the mains.
i Next time the mains is connected, a new learn is needed to be run, and the operator will use
the default values.
57Issue 2021-02-241005088-en-22.0
14 Advanced settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Assa Abloy SW100 and is the answer not in the manual?

Assa Abloy SW100 Specifications

General IconGeneral
BrandAssa Abloy
ModelSW100
CategoryDoor Opening System
LanguageEnglish

Related product manuals