CEC Client Installation 35
CEC Client Installation Supplemental Appendix for UP Xtreme
5.1.2 Routing Control
Command Feature: This feature is used to control the routing of the HDMI network by
controlling CEC Switches.
The following messages are used for the Routing Control feature: <Active Source>,
<Inactive Source>, <Request Active Source>, <Set Stream Path>, <Routing Change>,
<Routing Information>.
5.1.3 System Standby
Command Feature: The broadcast message <Standby> can be used to switch all CEC
devices to standby. The following message is used for the System Standby feature:
<Standby>
OpCode
Value
Description
Parameters
Response
Supported
<Standby>
0x36
Switches one or
all devices into
standby mode.
Can be used as
a broadcast
message or be
addressed to a
specific device.
None
Switch the device into
Standby. Ignore the
message if already in
standby.
Yes
5.1.4 One Touch Record
Command Feature: This feature allows the user to easily start a recording of the source
that is being displayed on the TV, just by selecting a Recording Device and giving the
record command.
The following messages are used for the One Touch Record feature: <Record Off>,
<Record On>, <Record Status>, <Record TV Screen>.
OpCode
Value
Description
Parameters
Response
Supported
<Record
Off>
0x0B
Requests a
device to stop a
recording.
None
Exit ‘Recording’ state.
Yes
Table Continues on Next Page