F100 5
5. Preserving the paver finisher
5.1 Shutdowns for up to 6 months
-
Grease all lube points in accordance with specifications. Allow optional
central lubricating unit to run if necessary.
-
Change oil in diesel engine.
-
Seal exhaust silencer to make it airtight.
-
Remove batteries, charge them and store them in a well ventilated place at
room temperature.
-
Park the vehicle in a place where it is protected from great exposure to direct
sunlight, wind, humidity and frost.
Recharge removed batteries every 2 months.
- Protect all bare metal components, e.g. piston rods on hydraulic cylinders,
with a suitable corrosion inhibitor.
- If it is not possible to park the vehicle is an enclosed building or under cover, it
must be covered with a suitable size of tarpaulin. In all cases, seal all air
intake and exhaust apertures with plastic film and adhesive tape.
5.2 Shutdowns lasting from 6 months to 1 year
- Carry out all the actions listed for "Shutdowns of up to 6 months".
- Once the engine oil has been drained off, fill the diesel engine with a
manufacturer approved grade of preserving oil.
5.3 Recommissioning the machine
- Reverse all the steps described in the "Shutdown" sections.