EasyManuals Logo

Atlas Copco Dynapac F3030C User Manual

Atlas Copco Dynapac F3030C
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #291 background imageLoading...
Page #291 background image
F100 5
5. Preserving the paver finisher
5.1 Shutdowns for up to 6 months
-
Grease all lube points in accordance with specifications. Allow optional
central lubricating unit to run if necessary.
-
Change oil in diesel engine.
-
Seal exhaust silencer to make it airtight.
-
Remove batteries, charge them and store them in a well ventilated place at
room temperature.
-
Park the vehicle in a place where it is protected from great exposure to direct
sunlight, wind, humidity and frost.
Recharge removed batteries every 2 months.
- Protect all bare metal components, e.g. piston rods on hydraulic cylinders,
with a suitable corrosion inhibitor.
- If it is not possible to park the vehicle is an enclosed building or under cover, it
must be covered with a suitable size of tarpaulin. In all cases, seal all air
intake and exhaust apertures with plastic film and adhesive tape.
5.2 Shutdowns lasting from 6 months to 1 year
- Carry out all the actions listed for "Shutdowns of up to 6 months".
- Once the engine oil has been drained off, fill the diesel engine with a
manufacturer approved grade of preserving oil.
5.3 Recommissioning the machine
- Reverse all the steps described in the "Shutdown" sections.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Dynapac F3030C and is the answer not in the manual?

Atlas Copco Dynapac F3030C Specifications

General IconGeneral
BrandAtlas Copco
ModelDynapac F3030C
CategoryConstruction Equipment
LanguageEnglish

Related product manuals