Version 6.8 81 Mediant MSBR
Configuration Guide 13. Loopback Interfaces
13.1.3 Example of Protocol Binding to Loopback Interfaces
The following is an example of Protocol Binding to Loopback Interfaces.
13.1.3.1 OAMP Binding to Loopback
In some cases, you may wish to bind the management protocols and interface to a
loopback interface on the MSBR, instead of a physical interface, so that management
protocols and messages will have to originate from and be addressed to this loopback
interface.
This can be configured as follows:
MSBR# configure data
MSBR(config-data)# interface loopback 1
MSBR(conf-if-Loopback 1)# ip address 1.1.1.1
MSBR(conf-if-Loopback 1)# description LOOPBACK
MSBR(conf-if-Loopback 1)#exit
MSBR(config-data)#exit
MSBR# config system
MSBR(config-system)# bind interface loopback 1 management-servers
13.1.3.2 118BBGP Termination on Loopback
It is common practice to terminate the BGP adjacency on loopback interfaces instead of
the physical interfaces, which provides more stability for the connection in case of
connectivity failure.

Table of Contents

Other manuals for AudioCodes Mediant MSBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant MSBR Series and is the answer not in the manual?

AudioCodes Mediant MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediant MSBR Series
CategoryNetwork Router
LanguageEnglish

Related product manuals