User's Manual 1112 Document #: LTRT-27045
Mediant 1000B Gateway & E-SBC
Parameter Description
FarEndDisconnectSilenceMethod to 1.
Silence Detection Period
[FarEndDisconnectSilencePeriod]
Defines the duration of the silence period (in seconds) after
which the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For the parameter to take effect, a device reset is
required.
Silence Detection Method
[FarEndDisconnectSilenceMethod]
Determines the silence detection method.
ï‚§ [0] None = Silence detection option is disabled.
ï‚§ [1] Packets Count = According to packet count.
Note: For the parameter to take effect, a device reset is
required.
[FarEndDisconnectSilenceThreshold]
Defines the threshold of the packet count (in percentages)
below which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Note:
ï‚§ The parameter is applicable only if silence is detected
according to packet count
(FarEndDisconnectSilenceMethod is set to 1).
ï‚§ For the parameter to take effect, a device reset is required.
[BrokenConnectionDuringSilence] Enables the generation of the BrokenConnection event during
a silence period if the channel’s NoOp feature is enabled
(using the parameter NoOpEnable) and if the channel stops
receiving NoOp RTP packets.
ï‚§ [0] Disable (default)
ï‚§
[1]
Enable
Trunk Alarm Call Disconnect
Timeout
trk-alrm-call-disc-to
[TrunkAlarmCallDisconnectTimeout]
Defines the duration (in seconds) to wait after a E1/T1/BRI
trunk "Red" alarm (LOS / LOF) is raised, before the device
disconnects the SIP call. If this timeout expires and the alarm
is still raised, the device sends a SIP BYE message to
terminate the call. If the alarm is cleared before this timeout
expires, the call is not terminated, but continues as normal.
The range is 1 to 3600. The default is 0 (20 for BRI, 20 for E1
and 40 for T1).
Disconnect Call on Busy Tone
Detection (ISDN)
disc-on-bsy-tone-i
[ISDNDisconnectOnBusyTone]
Determines whether a call is disconnected upon detection of a
busy tone (for ISDN).
ï‚§ [0] Disable = (Default) Do not disconnect call upon
detection of busy tone.
ï‚§ [1] Enable = Disconnect call upon detection of busy tone.
Note:
ï‚§ The parameter is applicable only to ISDN protocols.
ï‚§ IP-to-ISDN calls are disconnected on detection of SIT
tones only in call alert state. If the call is in connected
state, the SIT does not disconnect the calls. Detection of
busy or reorder tones disconnects the IP-to-
ISDN calls also
in call connected state.
ï‚§ For IP-to-CAS calls, detection of busy, reorder, or SIT
tones disconnect the calls in any call state.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals