Version 7.2 1113 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
Parameter Description
Disconnect Call on Busy Tone
Detection (CAS)
configure voip > gateway analog fxo-
setting > disc-on-bsy-tone-c
[DisconnectOnBusyTone]
Global parameter enabling call disconnection upon detection
of a busy tone.
You can also configure the functionality per specific calls,
using Tel Profiles (TelProfile_DisconnectOnBusyTone). For a
detailed description of the parameter and for configuring the
functionality in the Tel Profiles table, see Configuring Tel
Profiles on page 428.
Note: If the functionality is configured for a specific Tel Profile,
the settings of the global parameter is ignored for calls
associated with the Tel Profile.
Polarity (Current) Reversal for Call Release (Analog Interfaces) Parameters
configure voip > interface fxs-fxo >
default-linepolarity-state
[SetDefaultLinePolarityState]
Defines the FXO line polarity, required for DID signaling.
ï‚§ [0] = Positive line polarity
ï‚§ [1] = Negative line polarity
ï‚§ [2] = (Default) Auto - The device detects the polarity upon
power-up or upon insertion of the RJ-11 cable, and uses it
as a reference polarity.
Typically, if the RJ-11 cabling is connected correctly (without
crossing, Tip to Tip, Ring to Ring), the Tip line is positive
compared to the Ring line. In this case, set the parameter to 0.
With this configuration, the device assumes that the idle line
polarity is Tip line positive.
When the device receives a SIP INVITE, it checks the FXO
line polarity. If the polarity is "Reversed", it skips this FXO line
and goes to the next line.
Note:
ï‚§ For the parameter to take effect, a device reset is required.
ï‚§ To take advantage of this new feature, configure all FXO
lines as a single Trunk Group with ascending or
descending channel select mode, and configure routing
rules to route incoming INVITE messages to this Trunk
Group.
ï‚§ The parameter is applicable only to FXO interfaces.
Enable Polarity Reversal
configure voip > sip-definition
settings > polarity-rvrsl
[EnableReversalPolarity]
Global parameter enabling the Line Polarity Reversal feature
for call release.
You can also configure the functionality per specific calls,
using Tel Profiles (TelProfile_EnableReversePolarity). For a
detailed description of the parameter and for configuring the
functionality in the Tel Profiles table, see Configuring Tel
Profiles on page 428.
Note:
ï‚§ The parameter is applicable to FXS and FXO interfaces.
ï‚§ If the functionality is configured for a specific Tel Profile,
the settings of the global parameter is ignored for calls
associated with the Tel Profile.
Enable Current Disconnect
configure voip > sip-definition
settings > current-disc
[EnableCurrentDisconnect]
Global parameter enabling call release upon detection of a
Current Disconnect signal.
You can also configure the functionality per specific calls,
using Tel Profiles (TelProfile_EnableCurrentDisconnect). For

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals