56
2. If the displayed version is older than BIOS/FW/Boot:7.11-0 / Driver: 1.2-1, update it.
a. Download the 81605z_fw_b33173.zip file a
nd copy it to the /data/public/
folder.
b. Decompress 81605z_fw_b33173.zip file to /data/public/
81605z_fw_b33173/ folder.
unzip -o /data/public/81605z_fw_b33173.zip -d /data/public/
81605z_fw_b33173/
c. Update the RAID:
y | /usr/StorMan/arcconf romupdate 1 /data/public/81605z_fw_b33173/
AS816Z01.ufi
d. Reboot the FastServe server.
e. Check the RAID controller version after update. It should be BIOS/FW/Boot: 7.11-0
(33173) / Driver: 1.2-1.
/usr/StorMan/arcconf getconfig 1 | grep -E "BIOS|Firmware|Driver|Boot
Flash" | grep -v "T907"
f. Start your FastServe server.
/data/VS/bin/set_run -a all
To check and rebuild RAID:
1. Check the status of the RAID:
/usr/StorMan/arcconf getconfig 1 | grep “Group [0-9], Segment [0-9]”
/data/VS/bin/detect_raid_sgs
2. If the displayed status indicates that there is no sg3 - sg18 or RAID needs to be rebuild,:
a. Stop OVS:
/data/VS/bin/set_run -s all
b. /usr/StorMan/arcconf delete 1 logicaldrive all
c. Confirm by pressing the “y” and Enter keys on the keyboard.
d. Shut the system down.
shutdown -h now
e. Perform a power cycle and remove the power cables for about a minute. Remove all
additional devices connected to your machine, such as USB devices or additional hard
drives.
f. Turn the system back on, and after ca 3 minutes, stop the RAID and rebuild it:
/data/VS/bin/setupAACRaid6
g. Check the results:
/usr/StorMan/arcconf getconfig 1 | grep "Group [0-9], Segment [0-9]"
/data/VS/bin/detect_raid_sgs
3. Start the FastServe server.
4. Install the appropriate NEXIS Client from the WebSettings and update the Avid Registry.
5. To make sure the current firmware is appropriat
e for the CentOS7 version, reburn it using the
FastServe WebSettings. For more information, see the Administrator’s Guide.