EasyManua.ls Logo

Avid Technology FastServe Live Edit - Page 56

Avid Technology FastServe Live Edit
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
2. If the displayed version is older than BIOS/FW/Boot:7.11-0 / Driver: 1.2-1, update it.
a. Download the 81605z_fw_b33173.zip file a
nd copy it to the /data/public/
folder.
b. Decompress 81605z_fw_b33173.zip file to /data/public/
81605z_fw_b33173/ folder.
unzip -o /data/public/81605z_fw_b33173.zip -d /data/public/
81605z_fw_b33173/
c. Update the RAID:
y | /usr/StorMan/arcconf romupdate 1 /data/public/81605z_fw_b33173/
AS816Z01.ufi
d. Reboot the FastServe server.
e. Check the RAID controller version after update. It should be BIOS/FW/Boot: 7.11-0
(33173) / Driver: 1.2-1.
/usr/StorMan/arcconf getconfig 1 | grep -E "BIOS|Firmware|Driver|Boot
Flash" | grep -v "T907"
f. Start your FastServe server.
/data/VS/bin/set_run -a all
To check and rebuild RAID:
1. Check the status of the RAID:
/usr/StorMan/arcconf getconfig 1 | grep “Group [0-9], Segment [0-9]”
/data/VS/bin/detect_raid_sgs
2. If the displayed status indicates that there is no sg3 - sg18 or RAID needs to be rebuild,:
a. Stop OVS:
/data/VS/bin/set_run -s all
b. /usr/StorMan/arcconf delete 1 logicaldrive all
c. Confirm by pressing the “y” and Enter keys on the keyboard.
d. Shut the system down.
shutdown -h now
e. Perform a power cycle and remove the power cables for about a minute. Remove all
additional devices connected to your machine, such as USB devices or additional hard
drives.
f. Turn the system back on, and after ca 3 minutes, stop the RAID and rebuild it:
/data/VS/bin/setupAACRaid6
g. Check the results:
/usr/StorMan/arcconf getconfig 1 | grep "Group [0-9], Segment [0-9]"
/data/VS/bin/detect_raid_sgs
3. Start the FastServe server.
4. Install the appropriate NEXIS Client from the WebSettings and update the Avid Registry.
5. To make sure the current firmware is appropriat
e for the CentOS7 version, reburn it using the
FastServe WebSettings. For more information, see the Administrator’s Guide.