EasyManua.ls Logo

Avid Technology FastServe Live Edit - RAID Configuration

Avid Technology FastServe Live Edit
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
To edit the vsPreferences.cfg file:
1. Connect to your console with PuTTY or other terminal emulator.
n
The default vsPreferences.cfg file is created when OVS is run for the first time.
2. Open the vsPreferences.cfg file in the vim editor:
vim /data/VS/bin/vsPreferences.cfg
3. Edit the below settings:
t 51
6 CONTROL_NETWORK_INTERFACE=2 - set the eth port number which will be used
to connect to the network.
n
The Ethernet port number is specific to your configuration. In the example above, eth2 (10 Gb) is
used as the control network interface. For more information on Ethernet ports, see “Ethernet Ports”
on page 16.
t 51
7 DATA_NETWORK_INTERFACE=2– set the eth number which will be used for data
connection.
t 24 CODEC_FORMAT - check if the codec format matches the format set in the firmware
burning_status file.
t 20 ONLINE_MULTICAST_PORT=6666 – set the port number which will be used by
PIVOT and the FastServe | Live Edit Controller for communication with the server.
t RAID_LEVEL=60 – set the Raid level to 60.
t RAID_DISKS=1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 – make sure that the RAID uses all
available disks.
t change TASKS_MAX_HP_EXPORT=1 to TASKS_MAX_HP_EXPORT=8 under
[TASKS] line #607
t change RECORD_USE_BLACK_FILLER=0 to RECORD_USE_BLACK_FILLER=1
under [RECORD_EX] line #1361
4. To save and exit the file, type
:wq!
and press Enter.
n
For OP1a workflows, set the following option in the vsPreferences.cfg file:
EXPORT_OFFSETS_PROFILE=3
RAI
D Configuration
The following procedure describes the steps required when you need to chec
k the RAID.
To update the RAID:
1. Check the RAID controller version:
/usr/StorMan/arcconf getconfig 1 | grep -E "BIOS|Firmware|Driver|Boot
Flash" | grep -v "T907"

Table of Contents