3-56
Chapter 3 Starting and Stopping this Device
Calculation example:
ρ: 0.9
ρ
0
: 0.935 (general-purpose remote)
l: 1500 mm
h: 250 mm
d: 2000 mm
would result in:
0% liquid level differential pressure
LRV = (2000×0.935) - (250×0.9) = 1645 mm H
2
O = 16.13 kPa
100% liquid level differential pressure
URV = (2000×0.935) - (1500+250)×0.9
= 295 mm H
2
O = 2.893 kPa
Accordingly,
Low limit (LRV): 16.13 kPa
High limit (URV): 2.893 kPa
is the resulting range.