2-17
Chapter 2  Installation of this Device
(2)
 
Attachment of the transmitter side flange only to the process side flange  
First, attach the desired transmitter side flange to the process side flange. For information 
regarding flange attachment, see section 2-2-4. The transmitter can be attached to either the high 
pressure or low pressure flange.
Figure 2-21.   Process Side Flange Attachment 1
(3)
 
Attachment transmitter-adapter assembly to the flange 
Using four fastening bolts, securely fasten the transmitter, which was attached to the adapter in 
(1), to the transmitter side flange which was attached in (2).
Protective Pipe
Process Side
Process Side
Flange
Transmitter Side Flange
Adapter
Adapter Fastening Bolts
Remote Seal Type Dierential 
Pressure Transmitter
Figure 2-22.   Attachment to the Transmitter Side Flange