Loading...
168
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
MSI Check
Character
Transmission
Enables/disables transmission of an MSI check character.
MSI Length
Control
This feature specifies either variable length decoding or fixed length decoding for the MSI symbol-
ogy.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
MSI Check Character Transmission = Disable
MSI Check Character Transmission = Enable
CMSCT00(C
CMSCT01(C
DEFAULT
MSI Length Control = Variable Length
MSI = Fixed Length
DEFAULT
CMSLC00(C
CMSLC01(C