EasyManua.ls Logo

Balluff BVS HS-P Series - Page 172

Balluff BVS HS-P Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
172
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
Plessey Check
Character
Transmission
Enables/disables transmission of an MSI check character.
Plessey Length
Control
This feature specifies either variable length decoding or fixed length decoding for the Plessey
symbology.
Variable Length: For variable length decoding, a minimum and maximum length may be set.
Fixed Length: For fixed length decoding, two different lengths may be set.
Plessey Check Character Transmission =
Disable
Plessey Check Character Transmission =
Enable
PLCT00(CR
PLCT01(CR
DEFAULT
Plessey Length Control = Variable Length
Plessey = Fixed Length
DEFAULT
PLLC00(CR
PLLC01(CR

Table of Contents

Related product manuals