ex
11 Faults – causes and
remedies
Subject to technical modifications
Revision A / 04/2019
99 / 106
11.2.3 Notes on resetting the hand-held scanners
When using the BCS 3678
ex
Bluetooth version.
When using "Set Factory Default" the following settings are not reset.
- Multipoint-to-Point connection is not reset.
May have to be reset manually e.g. when updating the scanner firmware via Zebra 123
Scan Utility (only possible with activated point-to-point connection).
- Existing pairing connections are not reset/deleted.
Must be done manually by using the barcode "Unpairing" in the Zebra "Product Reference
Guide".
When using "Set Factory Default" the following settings are reset.
- When using the BCS 3678
ex
-IS the barcode for the status LED has to be scanned to adapt
the LED display to the Ex modifications.
Pairing with base station doesn’t work
Hand-held scanner is already connected to another base station
Unpair the hand-held scanner from the docking station or from the
PC/host to make the docking station available for pairing with another
digital device.
Scan the barcode below to disconnect all existing digital scanner
connections to docking station/PC host/other Bluetooth devices.
Unpairing
Further information on pairing methods can be found in the
corresponding Zebra "Product Reference Guide" in Chapter 4 - "Radio
Communication".
When "Factory Default Barcode" is scanned, all data is reset to factory settings but no existing
pairing connection is deleted.