6.6.3 Programming the interface parameters
Programming the universal supply module corded:
The universal supply module transmits the data of the serial interface 1 to 1.
In order to establish a connection with a PC, the interface parameters on the hand-held scanner and
the PC/host must be identical.
The interface parameters of the hand-held scanner can be adjusted via the programmable codes in the
Zebra product manual or by using the Zebra 123 Scan Utility.
The interface parameters of the PC/host can be adjusted via the settings e.g. in the device manager.
Programming the universal supply module Bluetooth:
The Bluetooth hand-held scanner is connected to the USM via Bluetooth.
Interface parameters cannot therefore be adjusted on the Bluetooth hand-held scanner (e.g. by
scanning programmable codes or via 123 Scan Utility).
The settings are made directly on the USM Bluetooth.
There is a separate manual for programming on the BARTEC Support Download page.
http://automation.bartec.de/indexE.htm
The manual describes the programming of the baud rate via a terminal program. The Bluetooth USM
must be connected to a PC via a serial interface (RS232 or USB-SPP). A terminal program is required
on the PC to transfer the settings.
Programming of the hand-held scanner:
The interface parameters of the hand-held scanner can be adjusted via the programmable codes in