Installation
Operation manual b maXX BM4100 (NWR)
Document no.: 5.04052.09
75
of 142
7
Figure 33: Connections of the controller part
UH1:green: Programmable LED
yellow: Programmable LED
UH2:green: Programmable LED
yellow: Programmable LED
H1: green: Supply
yellow: Feedback
H2: green: Enable
yellow: Power ON
H3: red: Current limit reached
H4: red: Error
X4: reserved
6: DTR, DSR
7: RTS
8: CTS
9: reserved
1: reserved
2: TxD RS232
3: RxD RS232
4: DTR, DSR
5:
Ground RS232
H5 display:
7 segment display
Standard operation Display drive status
Error condition: Display error number
X2:
Connection for
Baumüller memory module PSI ***
X3-1: BB on (no contact) (SELV/PELV)*
X3-2: BB-On (middle reversing switch)
(SELV/PELV)
*
X3-3: Reference potential for 4 and 5
(SELV/PELV)*
X3-4: Error reset (SELV/PELV)*
X3-5: Pulse enable (SELV/PELV)*
X3-6: BB-ON (NC contact) (SELV/PELV)*