55
®®
Section 3 - Programming from PC
If you associate any of the signals in the last section to a ‘NON Monostable’
Output, the Output will restore when the cause of activation clears (automati-
cally or manually).
For example, the “Entry Time” signal will activate the Output for the pro-
grammed Entry Time, then will restore automatically to standby.
However, if an Output is activated by a “... Tamper” signal, it will not restore
to standby until the cause of its activation clears.
z Valid Code (Code) - The Output will activate when the Control panel rec-
ognizes a Valid Code. This signal can be associated with ‘Monostable’ Out-
puts only.
z Squawk (Squawk) - The Output will activate when the Control panel is
Armed via a Command Zone or Remote Command. This signal can be asso-
ciated with ‘Monostable’ Outputs only.
z Failed call (Fail com) - This event is generated by unsuccessful calls.
To restore the Output:
a) view the Event logger on an LCD Keypad;
b) view the Trouble on an LED Keypad.
z Inactivity (Inactiv.) - The Output will activate when the Control panel gen-
erates an ‘Inactivity’ event. The Output will restore when the Alarm
memory resets (via a ‘Clear Alarm Memory’ command).
z Mute Alarm (Silent) - The Output will activate when the Alarm is gener-
ated by a Zone that is assigned to a Partition with the following attributes:
a) Type ‘Duress’, b) Attribute ‘Mute’ or
c) If the Alarm is generated by a ‘Duress’ Code.
This signal can be associated with ‘Monostable’ Outputs only.
z Not Ready Stay (N.R.Stay) - The Output will activate when the Control
panel is not ready to arm in ‘Stay’ mode (S) or, in accordance with Option 52
(refer to the Options Page), ‘Stay 0 Delay’ mode.
z Not Ready Away (N.R.Away) - The Output will activate when the Control
panel is not ready to arm in ‘Away’ mode.
z Stay (Stay Arm) - The Output will activate when at least one of its Partitions
Arms in ‘Stay’ mode (‘S’ or ‘0’).
z Restore if on standby (Al.r.zon) - The Output will activate when Alarm condi-
tions are detected on one of its Partitions. The Output will restore when the Alarm
cycle ends, and the Alarm conditions have been cleared from all the Partition zones,
or when the Partition disarms.
z False key (FalseKey) - The Output will activate when an attempt is made to
use a False Key. This is real-time event, therefore, the Output cannot restore
until the False key has been removed.
z Zone Tamper (ZoneTamp) - The Output will activate when Zone Tamper
conditions are detected, and will remain active during the respective Alarm
cycles.