75
®®
Section 3 - Programming from PC
z Stop siren during Listen-in (36) - If this option is enabled, the Alarm siren
will be inhibited during Listen-in and 2-Way Audio sessions.
z Lock keypad on invalid Code (37) - If this option is enabled, entry of 5
‘Wrong codes’ will lock the Keypad for 2 minutes.
z Arm/Disarm Voice Message (38) - If this option is enabled, it will be
possible to play the voice messages for the following events:
Exit Time Continuous playback of Message no. 6
Entry time Continuous playback of Message no. 7
Auto-arm Timeout Continuous playback of Message no. 8
For further information regarding Voice Messages, refer to the MAIN UNIT
MANUAL.
z Quick Arming (39) - If this option is enabled, the User will be able to Arm
a Partition by simply entering the Partition number and pressing ON (refer to
“Operating from a Keypad” in the USER MANUAL).
z Enable redundant arming on Partition 1 - 8 (40 through 47) - If this
option is enabled, the Control panel will generate a ‘Disarm’ event also when
the Partition is disarmed. If the event is associated with an Output, the Con-
trol panel will activate the Output concerned. This option is for Codes/Keys
with the ‘And’ attribute (refer to “And” in the Attributes section). The Out-
put will not activate until all the respective Keys and Codes have been used
within the programmed window.
z Enable Autoarm on Keypad and PROXI (48) - If this option is enabled,
the system Keypads and PROXI Readers will emit and audible signal
(beeps) during the ‘Timeout-to-autoarm’ (refer to option 24 — ‘Buzzer on
PROXI Reader’).
z Inhibit DTMF functions during message playback (49) - If this option is
enabled, the Control panel will deny access to the DTMF Menu during Voice
calls. However, the Answerphone functions, via the DTMF Menu, will still
be available’.
z Deny Arming during Control panel trouble (50) - If this option is ena-
bled, the Control panel will not accept arming commands when it detects
‘System Trouble’ (signalled on the G indicator).
z Special Events for Stay Arming (51) - If this option is enabled, the Stay
(S) and Stay 0 Delay (I) Arming events will be logged as Eventi Speciali.
Furthermore, Special Arming events (DTMF, Autoarm, Arming from PC or
Command Zone) will be logged as Normal Arming events.
z Include Delayed zones in the ‘Not-Ready-Stay’ output evaluation
(52) - If this option is enabled, the Control panel will activate the ‘Not-
Ready-Stay’ output when it detects violation on any type of zone. If this
option is disabled, the Control panel will activate the ‘Not-Ready-Stay’ out-
put when it detects violation on Instant zones ONLY. For further details refer
to the Outputs Page under ‘Not Ready Stay’ in the ‘Signals’ section.
z Serial Port Events (53) - If this option is enabled, any Events recorded in
the Event Logger will also be sent via the RS232 Serial Port.
NOTE: If this option is enabled, communications with the PC will be
inhibited.