Operation
BEUMER stretch hood® S
76 BA-6090103-EN
19.08.09
Parameters Function Note
044 Waiting time - lower hoist
carts, standard stretch
This parameter defines the waiting time
of the hoist carts after the film hood has
been stretched (standard stretch). The
waiting time is calculated from the pa-
rameter value multiplied by the factor
0.1 s.
046 Waiting time - lower hoist
carts, high-rack stretch
This parameter defines the waiting time
of the hoist carts after the film hood has
been stretched (high-rack stretch). The
waiting time is calculated from the pa-
rameter value multiplied by the factor
0.1 s.
048 Waiting time - lower hoist
carts, sleeve
This parameter defines the waiting time
of the hoist carts after the film hood has
been stretched (sleeve). The waiting
time is calculated from the parameter
value multiplied by the factor 0.1 s.
052 Correction value of the
hood length for standard
stretch
The parameter value is added to the
measured package height. The result
corresponds to the hood length.
054 Correction value of the
hood length for high-rack
stretch
The parameter value is added to the
measured package height. The result
corresponds to the hood length.
056 Crimp film hood
fter sealing, the excess film in the
upper area of the film hood is crimped.
058 Crimp sleeve Once the film has been cut, the excess
film is pulled over the crimping bows.
060 Speed of stretch car-
riages during stretching
This parameter defines the speed of
the stretch carriages when the film
hood is stretched.
062 Move back crimping mo-
tors during stretching
During the stretching process, the
crimping motors are moved back for a
short time once this position is
reached.
064 Press on crimping mo-
tors during stretching
The crimping motors, which have been
moved back for a short time during the
stretching process, are advanced once
this position is reached.
066 Speed of stretch sleds
during stretching
This parameter defines the speed of
the stretch sleds when the film hood is
stretched.
068 Speed of hoist carts for
second stretching proc-
ess
This parameter defines the speed of
the hoist carts in the central area of the
package.