Operating instructions eS10 Operation
38034911005 en 41
5
5.12.4 Deleting tare
Key Display presentation Description on how to proceed
Display of net weight.
Display of gross weight.
5.12.5 Counting operation
Key <F1> is assigned with "Cnt" and a reference number such as 10 is preselected, see
page 26.
The device also serves as:
– Reference weight scale
Reference weight = weight of reference weight mass / number of reference parts
– Quantity scale
Number of pieces = weight of mass to be counted / reference weight
In order to calculate the reference weight accurately, the following lower limit applies to the
reference mass:
Reference weight mass ≥ weighing range / 600
This equals 200 x the internal fine division. An internal division step is the 120,000th part
of the weighing range.
Example
Weighing range: 30 kg
Scale interval: 10 g
Fine division: 0.25 g
Lower limit of reference weight mass: 50 g
Weighing
range
scale interval
subject to
metrological
approval
1d (internal) 200d Minimum reference weight at...
[kg]
Display interval
[g]
max.
120 000d [g]
min. reference
mass [g]
1)
Reference
number 10 [g]
Reference
number 20 [g]
≤ 10.00 ≤ 2 – ≤ 18 – –
≤ 15.00 ≤ 5 ≤ 0.125 ≤ 25 ≤ 2.5 ≤ 1.25
≤ 30.00 ≤ 10 ≤ 0.25 ≤ 50 ≤ 5 ≤ 2.5