EasyManua.ls Logo

Bizerba eS10 - Page 86

Bizerba eS10
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service menu Operating instructions eS10
84 38034911005 en
9
Selection
Subselection Display Explanation
or
30 1
Minimum load capacity
30 0
Minimum load 20 e
Setting changes with
each keystroke.
30 1
Minimum load 5 e for non-automatic weighing in-
struments of class III for the determination of
transportation rates.
or
31 000
Positive g factor, g/kg
Input 010 equals 0.10 g/kg
or
32 000
Negative g factor, g/kg
Input 050 equals -0.50 g/kg
or
33 1
Digital filter
33 0
No-motion environment, brief weighing time
Setting changes with
each keystroke.
33 1
No-motion environment, medium weighing time
to
33 9
Environment in motion, long weighing time
or
34 15
Time to establish no-motion of weight
Time = value x 30 ms
Minimum input = 8
or
35 05
Permissible deviation of measured value for
stable weight
Permissible deviation = value x 3 dd
Minimum input = 5
Special case dual interval scale 3/1. 5kg 1/0.5 g:
Step 22 = 3
Step 23 = 1
Step 24 = 2
Step 25 is preset with 1_5
Step 26 is preset with 0_5

Table of Contents

Related product manuals