30 1
Minimum load capacity
30 0
Minimum load 20 e
Setting changes with
each keystroke.
30 1
Minimum load 5 e for non-automatic weighing in-
struments of class III for the determination of
transportation rates.
or
31 000
Positive g factor, g/kg
Input 010 equals 0.10 g/kg
or
32 000
Negative g factor, g/kg
Input 050 equals -0.50 g/kg
or
33 1
Digital filter
33 0
No-motion environment, brief weighing time
Setting changes with
each keystroke.
33 1
No-motion environment, medium weighing time
to
33 9
Environment in motion, long weighing time
or
34 15
Time to establish no-motion of weight
Time = value x 30 ms
Minimum input = 8
or
35 05
Permissible deviation of measured value for
stable weight
Permissible deviation = value x 3 dd
Minimum input = 5
Special case dual interval scale 3/1. 5kg 1/0.5 g:
Step 22 = 3
Step 23 = 1
Step 24 = 2
Step 25 is preset with 1_5