| | | * Car calls on high priority operation
| | | - one alterable car call [Default]
| | | - collect car calls
| | | * Trip to high priority floor with no load only
| | | - off [Default]
| | | - on
| | | * Collect high priority calls
| | | - off [Default]
| | | - on
| | | * Prevent disabling of high priority landing calls
| | | - off [Default]
| | | - on
| | |
| | +- Group
| | | * Park mode
| | | - Fixed [Default]
| | | - Zoning
| | | - Lobby
| | | * Number of lobby cars parked
| | | none/1..8 [0]
| | | * Door opening on hall call
| | | - Open one car per floor only
| | | - Open one car per landing call [Default]
| | | - Open all cars on the floor
| | | * Multiple priority calls per floor
| | | - off [Default]
| | | - on
| | | * Penalty for car at lobby floor
| | | off/1..5 [1]
| | | * Penalty for lift parked
| | | off/1..5 [1]
| | | * Penalty for Blue Modus C
| | | 1..15 [8]
| | | * Penalty for Blue Modus B
| | | 1..31 [16]
| | | * Penalty for idle lift
| | | off/1..5 [3]
| | | * Penalty for car call stopping
| | | 1..16 [8]
| | | * Distance to floor factor
| | | 1..4 [1]
| | | * Penalty for directional change
| | | off/1..4 [2]
| | | * Send group settings to all active group members
| | | - off [Default]
| | | - Execute
| | |
| | +- Drive unit
| | | |
| | | +- Travelling speed
| | | | * V0 (Creeping velocity)
| | | | 0..16000 [50] mm/s
| | | | * V1
| | | | 0..16000 [0] mm/s
| | | | * V2
| | | | 0..16000 [0] mm/s
| | | | * V3
| | | | 0..16000 [0] mm/s
| | | | * V4
| | | | 0..16000 [0] mm/s
| | | | * V5
| | | | 0..16000 [0] mm/s
| | | | * V6
| | | | 0..16000 [0] mm/s
| | | | * V7
| | | | 0..16000 [0] mm/s
| | | | * VN (Releveling velocity)
| | | | 0..300 [10] mm/s
| | | | * VI (Inspection velocity)
| | | | 0..630 [500] mm/s
| | | | * VR (Emerg. rescue velocity)
| | | | 0..630 [500] mm/s
| | | | * Max. full load velocity
| | | | - V0 (Creeping velocity)
| | | | - V1
| | | |
| | | +- Slowing distance
| | | | * V0 (stopping dist.)
| | | | 0..65000 [35] mm
| | | | * V1
123