| | | off/1..60 [20] s
| | | * Door locking monitoring
| | | off/1..60 [10] s
| | | * Manual door monitoring time in group operation
| | | off/1..255 [off] s
| | | * Start control
| | | 1..45 [15] s
| | | * Driving monitoring
| | | 1..45 [45] s
| | | * Deceleration control
| | | 1..30 [15] s
| | | * Re-levelling control
| | | 1..45 [20] s
| | | * Pawl device monitoring lifting/lowering
| | | off/1..60 [10] s
| | | * Pawl device monitoring retract/extend
| | | off/1..60 [3] s
| | | * Pawl device monitoring re-pumping
| | | off/1..255 [5] s
| | | * Emergency power sequence monitoring
| | | off/30..255 [60] s
| | | * Emergency power enabling monitoring
| | | off/1..255 [off] s
| | | * Chemical operation monitoring time (timeout)
| | | off/1..255 [off] min
| | | * Automatic emergency rescue monitoring
| | | 1..255 [30] s
| | |
| | +- Drive unit times
| | | * Main contactor debounce time on
| | | off/1..1000 [100] ms
| | | * Main contactor on monitoring time/max. wait time
| | | off/1..3000 [1000] ms
| | | * Main contactor debounce time off
| | | off/1..1000 [100] ms
| | | * Main contactor off monitoring time/max. wait time
| | | off/1..3000 [1000] ms
| | | * Safety brake debounce time
| | | off/1..1000 [100] ms
| | | * Safety brake monitoring time
| | | off/1..3000 [1000] ms
| | | * Brake debounce time on
| | | off/1..1000 [100] ms
| | | * Brake monitoring time on
| | | off/1..3000 [1000] ms
| | | * Brake debounce time off
| | | off/1..1000 [100] ms
| | | * Brake monitoring time off
| | | off/1..3000 [1000] ms
| | | * Main contactor delayed off
| | | off/1..2000 [off] ms
| | | * Star-delta start
| | | off/1..5000 [1000] ms
| | | * Motor delayed off
| | | off/1..5000 [off] ms
| | | * Up-valve delayed close
| | | off/1..5000 [off] ms
| | | * Down-valve delayed close
| | | off/1..5000 [off] ms
| | | * Main contactor delayed off
| | | off/1..2000 [off] ms
| | | * Drive (motor) fan after-run time
| | | off/1..600 [off] s
| | | * Relevelling on delay time
| | | 0..10000 [1000] ms
| | | * Relevelling off delay time
| | | 0..5000 [0] ms
| | | * Homing time
| | | off/1..60 [15] min
| | | * Fast start activation delay time
| | | off/1..10000 [1000] ms
| | | * Automatic emergency rescue delay
| | | off/1..255 [20] s
| | | * Drop protection monitoring time after deactivation
| | | 500..5000 [500] ms
| | | * Pawl device run delay re-pumping
| | | off/1..5000 [100] ms
| | | * Pawl device end switches debounce time
| | | off/1..5000 [100] ms
| | |