| | | off/1..16 [off]
| | | * Parking in hidden position
| | | off/1..1200 [off] mm
| | | * Enable parking at floors with no doors
| | | - off [Default]
| | | - on
| | | * Control floor remote off
| | | off/1..16 [off]
| | | * Remote off floor
| | | off/1..16 [off]
| | | * Remote off in hidden position
| | | off/1..1200 [off] mm
| | | * Peak-up floor
| | | off/1..16 [off]
| | | * Peak-down floor
| | | off/1..16 [off]
| | | * Fire recall floor
| | | off/1..16 [off]
| | | * Alternate fire recall floor
| | | off/1..16 [off]
| | | * Emergency power floor
| | | off/1..16 [off]
| | | * Blue Modus floor
| | | off/1..16 [off]
| | | * Blue Mode in hidden position
| | | off/1..1200 [off] mm
| | | * Service floor
| | | off/1..16 [off]
| | | * Control floor generic
| | | off/1..16 [off]
| | | * Lift allocation floor
| | | off/1..16 [off]
| | | * Cleaning floor
| | | off/1..16 [off]
| | | * Docking service floor 1..8
| | | off/1..16 [off]
| | | * Fire alarm return floor 1..16
| | | off/1..16 [off]
| | |
| | +- Floor names
| | | * Floor text 1..127
| | | * Send floor text
| | | - off [Default]
| | | - on
| | |
| | +- Disable calls
| | | * Keep car call at lobby enabled, on signal "Disable all car calls"
| | | - off [Default]
| | | - on
| | | * Car calls disabled 1..127
| | | * Landing calls disabled 1..127
| | |
| | +- 7-segment displays
| | * Custom display encoding
| | - off [Default]
| | - on
| | * Bit mask floor 1..63
| |
| +- Temperatures
| | * Overtemperature comparator (238)
| | -55.0..125.0 [35.0] °C
| | * Undertemperature comparator (239)
| | -55.0..125.0 [7.0] °C
| | * Max. Machine room temperature
| | 10.0..125.0 [60.0] °C
| | * Min. Machine room temperature
| | -50.0..30.0 [-5.0] °C
| |
| +- Shaft encoding
| |
| +- Parameter
| | |
| | +- General ways
| | | * Shaft pit area
| | | 350..65000 [1000] mm
| | | * Shaft head area
| | | 350..65000 [1500] mm
| | | * Car height
| | | 500..10000 [2000] mm
| | | * Upper door zone
130