| | | * Unlock disabled floors
| | | - off
| | | - on [Default]
| | | * Ignore overload on fire service
| | | - off [Default]
| | | - on
| | | * Cancel remote off
| | | - off
| | | - on [Default]
| | | * Doors
| | | - Peep door function [Default]
| | | - Normal operation
| | | * Homing the car by turning off/on the fire recall (125) key within 5 s
| | | - on [Default]
| | | - off
| | | * Car calls need constant pressure
| | | - off [Default]
| | | - on
| | | * Close doors manually using the close-door button
| | | - off [Default]
| | | - on
| | | * Disable upper floor
| | | - off [Default]
| | | - on
| | | * Use alternate fire recall (475)
| | | - off [Default]
| | | - on
| | |
| | +- Emergency rescue
| | | * Emergency rescue
| | | - manually only [Default]
| | | - automatic and manual
| | |
| | +- Attendant service
| | | * Function
| | | - off [Default]
| | | - on
| | | * Adopt attendant service operation from lift group
| | | - off [Default]
| | | - on
| | | * Map hall call acknowledges on car call acknowledges
| | | - off [Default]
| | | - on
| | |
| | +- Access zones
| | | * Function
| | | - off [Default]
| | | - on
| | | * Zone preselection via impulse at the door table inputs (80, 380)
| | | - off [Default]
| | | - on
| | | * Zone preselection floor
| | | off/1..16 [off]
| | |
| | +- Group
| | | * Park mode
| | | - Fixed [Default]
| | | - Zoning
| | | - Lobby
| | | * Number of lobby cars parked
| | | none/1..8 [0]
| | | * Door opening on hall call
| | | - Open one car per floor only
| | | - Open one car per landing call [Default]
| | | - Open all cars on the floor
| | | * Multiple priority calls per floor
| | | - off [Default]
| | | - on
| | | * Penalty for car at lobby floor
| | | off/1..5 [1]
| | | * Penalty for lift parked
| | | off/1..5 [1]
| | | * Penalty for Blue Modus C
| | | 1..15 [8]
| | | * Penalty for Blue Modus B
| | | 1..31 [16]
| | | * Penalty for idle lift
| | | off/1..5 [3]
| | | * Penalty for car call stopping
| | | 1..16 [8]
146