| | | * Distance to floor factor
| | | 1..4 [1]
| | | * Penalty for directional change
| | | off/1..4 [2]
| | | * Send group settings to all active group members
| | | - off [Default]
| | | - Execute
| | |
| | +- Guest Calls
| | | * Function
| | | - off [Default]
| | | - on, send lift by car call only
| | | - on, send lift by hold time expired
| | | - on, send lift by car call or hold time expired
| | | - on, send lift by enable signal only
| | | - on, send lift by enable signal or hold time expired
| | | * Allow entering of new car calls while waiting to proceed guest calls
| | | - off [Default]
| | | - on
| | | * Landing calls on guest operation
| | | - collective [Default]
| | | - cancel
| | | * Start to pickup floor on no-load if doors closed
| | | - off [Default]
| | | - on
| | | * Clear car calls if guest operation is activated
| | | - off [Default]
| | | - on
| | |
| | +- Key switch
| | | * Key switch 1 bistable
| | | - off [Default]
| | | - on
| | | * Key switch 2 bistable
| | | - off [Default]
| | | - on
| | | * Key switch 3 bistable
| | | - off [Default]
| | | - on
| | | * Key switch 4 bistable
| | | - off [Default]
| | | - on
| | |
| | +- Handicapped access
| | | * Handicapped accessible calls
| | | - off [Default]
| | | - on
| | |
| | +- Chemical Operation
| | | * Function
| | | - off [Default]
| | | - on, on-neutral-off key switch 3-state
| | | - on, key-button/card reader on landings
| | | - on, activation in the car
| | |
| | +- Earth quake evacuation operation
| | | * Function
| | | - off [Default]
| | | - on
| | | * Unlock disabled floors
| | | - off
| | | - on [Default]
| | | * Cancel remote off
| | | - off [Default]
| | | - on
| | | * Evacuate an idle lift too
| | | - off [Default]
| | | - on
| | |
| | +- Docking service
| | | * Function
| | | - off [Default]
| | | - on, type 1 simple docking operation
| | | - on, type 2 underfloor lift
| | | * Docking service position range
| | | 50..4000 [500] mm
| | | * Generic docking service velocity
| | | - V0 (Creeping velocity) [Default]
| | | - V1
| | | - V2
147