Silent alarm/chime mode (0 = disabled, 1 = silent
alarm, 2 = chime mode, 3 = both)
1003 0
VDS-A
EN=0/2
Pulse count (0 = disabled, 1 – 9 = 1 – 9 times) 1004 0
VDS-A EN=0
Zone lockout (0 = disabled, 1 = 1 time, 2 = 3
times, 3 = 6 times, 4 = alarm duration)
1005 3
Zone DEOL (0 = disabled, 1 = DEOL, 3 = NC, 4 =
NO) (3 and 4 are not applicable for wireless
zones)
1006 1
Report (1 = receiver 1,
2 = receiver 2,
3 = receiver 3,
4 = receiver 4,
5 = receiver 1, 2, 3, 4,
6 = receiver 1 (2, 3, 4 backup)
7 = receiver 1 (2 backup) and receiver 3 (4
backup))
1007 6
VDS-A
EN=1/5/6/7
Cross zone/unverified alarm (0 = disabled, 1 =
unverified alarm, 2 = cross zone, 3 = both)
1008 0
VDS-A EN=0
Domestic no. (1 = dom. 1,
2 = dom. 2,
3 = dom. 3,
4 = dom. 4,
5 = dom. 1, 2, 3, 4,
6 = dom. 1 (2, 3, 4 backup)
7 = dom. 1 (2 backup) and dom. 3 (4 backup))
1009 0
Zone reaction time (unit: x100ms) 1010 – 1013 0003
01 (as an
example for the
following zone
functions 02 to
15)
Selection of a zone type* 1015 – 1016 01
Allow bypass/force arm 1017 3
VDS-A
EN=0/2
Silent alarm/chime mode 1018 0
VDS-A
EN=0/2
Pulse count 1019 0
VDS-A EN=0
Zone lockout 1020 3
Zone DEOL 1021 1
Report 1022 6
VDS-A
EN=1/5/6/7
Cross zone/unverified alarm 1023 0
VDS-A EN=0
Domestic no. 1024 0
Zone reaction time 1025 – 1028 0003
*For an explanation of the zone types, refer to Add / Delete Zone, page 49.
124
en | Address Programming AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH