For the zone functions 02 to 15 the same options as for zone functions 01 can be programmed
with the same number of addresses for each option:
– Selection of a zone type: 2 addresses each
– Allow bypass/force arm: 1 address each
– Silent alarm/chime mode: 1 address each
– Pulse count: 1 address each
– Zone lockout: 1 address each
– Zone DEOL: 1 address each
– Report: 1 address each
– Cross zone/unverified alarm: 1 address each
– Domestic no.: 1 address each
– Zone reaction time: 4 addresses each
The default values for zone functions 02 to 15 are the same as the default values of zone
functions 01, except for the option “Selection of a zone type”.
The following addresses are used for programming the zone functions 02 to 15:
Zone function
Option Address Default
02 Selection of a zone type* 1030 – 1031 02
Remaining options as shown above 1031 – 1043 3003160
00003
03 Selection of a zone type* 1045 – 1046 03
Remaining options as shown above 1047 – 1058 3003160
00003
04 Selection of a zone type* 1060 – 1061 04
Remaining options as shown above 1062 – 1073 3003160
00003
05 Selection of a zone type* 1075 – 1076 05
Remaining options as shown above 1077 – 1088 3003160
00003
06 Selection of a zone type* 1090 – 1091 06
Remaining options as shown above 1092 – 1103 3003160
00003
07 Selection of a zone type* 1105 – 1106 07
Remaining options as shown above 1107 – 1118 3003160
00003
08 Selection of a zone type* 1120 – 1121 08
Remaining options as shown above 1122 – 1133 3003160
00003
09 Selection of a zone type* 1135 – 1136 09
Remaining options as shown above 1137 – 1148 3003160
00003
10 Selection of a zone type* 1150 – 1151 10