7 6 1 Keypad Lock out
7 7 RF receiver tamper
7 7 1 RF receiver tamper
7 8 RF repeater tamper
7 8 1 – 8 RF repeater tamper
8 External failure
8 1 - 16 External fault zone 1 - 16
Table 10.1: Types of fault or tamper conditions
* In case one or more faults occur in this category
Fault Description
1 - Accessory Module Failure
– Network/IP Module 1-2 Failure
Condition:
No communication with the DX4020 / ITS-DX4020G if DX4020 / ITS-DX4020G is available.
Restore:
4 Restore the communication with DX4020 / ITS - DX4020G to a normal condition and reset
the fault. For more information, refer to DX4020-G, page 22.
Supervise:
1. Report the DX4020 / ITS - DX4020G fault to configured destination on address 124 when
the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off, when there is no other system fault.
– Output Expansion Module 1-2 Failure
Condition:
No communication with DX3010 if DX3010 is available.
Restore:
4 Restore the communication with DX3010 to a normal condition and reset the fault. For
more information, refer to DX3010, page 18.
Supervise:
1. Report the DX3010 fault to configured destination on address 140 when the fault is
detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off, when there is no other system fault.
– Input Expansion Module 1-6 Failure
Condition:
No communication with DX2010 if DX2010 is available.
Restore:
4 Restore the communication with DX2010 to a normal condition and reset the fault. For
more information, refer to DX2010, page 16.
Supervise:
142
en | Troubleshooting AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH