Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
3. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– Bosch Option Bus Power 1-2 Failure
Condition:
Bosch option bus power supply voltage is lower than 9V+-5%.
Restore:
4 Raise the voltage to 12V and reset the fault. For more information refer to Bosch Option
Bus, page 13.
Supervise:
1. Monitor the voltage by MPU.
2. Report the Bosch Option Bus Power Supply fault to the configured destination
programmed on address 124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
3. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Repeater 1-8 AC Power Failure
Condition:
1. AC power failure to the repeater.
2. The repeater is not wired correctly, if a wireless module is enabled.
Restore:
4 Restore the repeater AC power and reset the fault.
Supervise:
1. Report the repeater AC power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Repeater 1-8 Battery Failure
Condition:
The repeater is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the repeater battery and reset the fault. For more information refer to RF Devices,
page 78.
Supervise:
1. Report the repeater battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Sensor Power Failure
Condition:
The sensor is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the sensor battery and reset the fault. For more information refer to RF Devices,
page 78.
Supervise:
AMAX 2100 / 3000 / 4000
Troubleshooting | en 147
Bosch Sicherheitsysteme GmbH Installation Guide 2014.11 | 02 | F.01U.267.112