1. Report the sensor power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Keyfob Battery Failure
Condition:
The keyfob is in a low battery condition if a wireless module is enabled.
Restore:
4 Restore the keyfob battery and reset the fault. For more information refer to RF Devices,
page 78.
Supervise:
1. Report the keyfob battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
3 -Output Failure
– Onboard Output 1-2 Fault
Condition:
An onboard output is in a short circuit or open circuit condition.
Restore:
4 Restore the onboard output to a normal condition and reset the fault. For more
information refer to Outputs, page 71.
Supervise:
1. Report the onboard output 1-2 fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
4 -Keypad Failure
– Keypad 1-16 failure
Condition:
No communication between the panel and a keypad.
Restore:
4 Restore the communication between the panel and the keypad and reset the fault. For
more information refer to Keypad Area, page 65.
Supervise:
1. Report the keypad fault to the configured destination programmed on address 124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 10 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
5- System Failure
– Date and Time not set
Condition:
148
en | Troubleshooting AMAX 2100 / 3000 / 4000
2014.11 | 02 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH