Digit Required Number to Program Digit Required Number to Program
0 0 8 8
1 1 9 9
2 2 * 11
3 3 # 12
4 4 4 sec pause 13
5 5 Terminal 15
6 6
7 7
Table 7.1: Dialing Digits
How to program an IP address and port:
1. Use no punctuation in the IP address.
2. If any unit of the IP address has less than 3 digits, use 0 to fulfill the data in the higher
bits.
3. The remaining 5 digits program the port. Port number ranges from 0-65535.
4. If a port number has less than 5 digits, use 0 to fulfill the data.
Example
4 To program the IP Address “10.16.1.222:80” as the IP address of receiver 1, enter the
following sequence into address 000 – 016:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Notice!
Programming option anti-replay, acknowledge wait time, and pulse interval time are only used
in Conettix IP.
Telephone number for Receiver 1 - 4/IP Address and Port
When the corresponding data format for above programming address is a network
communication format, it is explained as an IP address, and port. For a non network format, it
is explained as a telephone number.
The AMAX panel contacts the telephone number / IP Address of the central monitoring station
in order to transmit a report. If the contact is successful, the relevant information is
transmitted, and the communicator returns to standby mode.
Contact your monitoring station for the correct telephone number / IP address before you
program these addresses.
Receiver Subscriber ID Number
Receiver 1 - 4 Subscriber ID Number
The subscriber ID number is transmitted to identify the calling AMAX panel. Only digits from 0
to 9. SIA DC09 supports letters from A to F.
1. Enter the subscriber ID number in the six addresses provided for each destination.
2. If a subscriber ID number has less than 6 digits, use 0 to full fill the data in the higher
bits.
Example
4 Program subscriber ID number as 4729 in six addresses: [0 0 4 7 2 9]