Description Symbol Unit XMD1-W2323 XMD1-W5454 XMD1-W7070
Rated power consumption control
voltage input at U
N3
8)
P
N3
W 127 160
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
9)
U
LN_nom
V DC 254 ... 750
Rated input current
I
LN
A DC 18.8 DC 47.6 DC 61.7
Required wire size in accordance
with NFPA 79 and UL 508 A
(internal wiring);
10)
A
LN
AWG 14 8
Field wiring material (material;
conductor temperature; class)
Cu; 75 °C; 1
Output voltage
U
out
V AC 0 ... 500
Output current
I
out
A
Axis 1: AC 7.7
Axis 2: AC 7.7
Axis 1: AC 27
Axis 2: AC 27
Axis 1: AC 35
Axis 2: AC 35
Output frequency range
11)
f
out
Hz 0 ... 1600
1) 2) 3) Housing dimensions
4) 5) 6) See fig. "Air intake and air outlet at device"
7) Observe supply voltage for motor holding brake
8) See information on "Rated power consumption control voltage
input at U
N3
"
9) Mains input L1, L2, L3; For use on a solidly grounded wye
source only.
10) Copper wire; PVC-insulation (conductor temperature 75 °C;
T
a
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
UL 508A chapter 28
11) Depending on switching frequency which was set in parameter
P‑0‑0001
Tab. 7-2: UL ratings and dimensions
UL ratings and dimensions (XMQ1-WQ001)
Description Symbol Unit XMQ1-WQ001
Listing in accordance with UL
standard
UL 61800-5-1
Listing in accordance with CSA
standard
C22.2 No. 274-17
UL files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Mass m kg 10
Device height
1)
H mm 309
Device depth
2)
T mm 196.5
Device width
3)
B mm 200
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
33/123
Technical data
R911392532_Edition 01 Bosch Rexroth AG

Table of Contents