11-6
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual System Programming
Part Entry Time
060 Seconds
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the required delay for the Part
Entry Time in seconds. Valid times are 0 - 255 seconds, 0 = No
Part Entry Time.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Auto Arm Pre-Alert
MENU 7-2-4
0 1 0
(*** System Wide Parameter ***)
Minutes
This menu allows you to program the Auto Arm Pre Alert count
down timer. The timer is used to warn sta or users that the
system is about to auto arm by sounding a tone on the keypad.
To set up auto arming see MENU 7-5-0 — System Schedules.
If a valid PIN + [OFF] is entered, the tone will stop and the keypad
will prompt the user to either abort or delay the automatic
arming. If the user selects the option to delay the auto arm,
this sequence will repeat on the hour untill the system is armed
manually or automatically.
For example if the system is programmed to auto arm at 8.00pm
and the Pre Alert time is set to 10 minutes then at 7.50pm the
system will begin sounding the Pre Alert tone on the keypad.
1) Press [MENU] + [7] + [2] + [4]. The keypad will display the
current Pre-Alert Time.
Auto Arm Pre Alert
010 Minutes
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the pre-alert time . Valid times
are 0 to 255 minutes. 0 = No Auto Arm Pre Alert.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Output Pre-Alert
MENU 7-2-5
0 0 0
(*** System Wide Parameter ***)
Minutes
The panel can be programmed to automatically operate an
output via a schedule, see MENU 7-5-0 — System Schedules.
This menu allows you to program the Output Pre Alert count
down timer. The timer is used to warn sta or users that an
output is about to operate by sounding a tone on the keypad.
1) Press [MENU] + [7] + [2] + [5]. The keypad will display the
current Output Pre Alert Time.
Output Pre Alert
000 Minutes
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the pre-alert time. Valid times
are 0 to 255 minutes. 0 = No Output Pre Alert
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Senior Watch Time
MENU 7-2-6
0 0 0
(*** System Wide Parameter ***)
Hours
This feature can be used to verify that an elderly person is OK or
as a dead man timer for an onsite patrolman or security ocer.
This menu allows you to program the Senior Watch Time period.
The panel must register at least one burglary zone in the
programmed area to unseal and reseal during this time period
or the panel will report a Senior Watch alarm to the base station.
A Senior Watch Restore will be sent when at least one zone is
unsealed and resealed. Senior Watch monitoring is only active
when the corresponding area is in the disarmed state.
i
Note
Software Version 1.02 and higher corrected. Previous versions
could generate spurious dead man reports if an area had senior
watch programmed and the senior watch time programmed as
zero.
1) Press [MENU] + [7] + [2] + [6]. The keypad will display the
current senior watch time. (default = 0 hours).
Senior Watch Time
000 Hours
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new senior watch time. Valid
times are 0 to 255 hours. 0 = No Senior Watch Time.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
SYSTE M P OW E R O PT ION S
System > Power >
AC Options
MENU 7-3-0
1 Display AC Fail Y
2 Report AC Fail Y
3 Use AC To Synchronise The System Clock Y
4 Random AC Report 2hour N
5 AC Fail After 1 hour N
6 Reserved N
7 Reserved N
8 Display Clock Trouble Y
This menu option allows you to congure the AC Mains Power
system options. (*** System Wide Parameter ***)