9-11
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Comms Programming
TX Format Dest 2 P001
01 - Contact ID
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Transmission
Format required then Press [OK] to save and exit or press
[MENU] to exit without saving.
i
Note
Option 14 - SMS - No Parity, is only available in version 1.02 or
higher.
Comms > Dialler Reporting
Test Route
MENU 5-4-2
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs which destination will be used to send
both manual and automatic test reports.
(*** System Wide Parameter ***)
1) Press [MENU] + [5] + [4] + [2]. The keypad will display the
current Test Route.
Test Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test Route
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
Comms > Dialler Reporting
Status Route
MENU 5-4-3
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu sets the report destination that will be used to send
all system event reports.
(*** System Wide Parameter ***)
1) Press [MENU] + [5] + [4] + [3]. The keypad will display the
current Status Report route.
Status Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test Route
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
Comms > Dialler Reporting
Emergency Route
MENU 5-4-4
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs the destination that all Keypad emergency
alarms are reported.
(*** System Wide Parameter ***)
1) Press [MENU] + [5] + [4] + [4]. The keypad will display the
current Emergency Route.
Emergency Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Keypad
Emergency route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Dialler Reporting >
Swinger Dialler
MENU 5-4-5
(*** System Wide Parameter ***)
0 6
Swinger Dialler can be used to prevent a faulty or run-a-way PIR
from continually re-triggering the zone and reporting to the
base station.
The Swinger Dialler count sets the maximum number of times
an individual zone can trigger an alarm during the current
arming cycle before it is locked out.
If this option is not programmed, the panel will continue to
report the alarm signal until the system or area is disarmed.
Only zones that have been programmed for Lockout Dialler in
MENU 3-1-7 Report Options will follow the Swinger Dialler
count.
1) Press [MENU] + [5] + [4] + [5]. The keypad will display the
current Swinger Dialler count.
Swinger Dialler
6
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new Swinger Dialler count
then press [OK] to save and exit or press [MENU] to exit
without saving. Valid entries are 0 - 15 / 0 = disabled.

Table of Contents

Other manuals for Bosch Solution 16plus