9-12
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Comms Programming
Comms > Dialler Reporting >
Burg Report Delay
MENU 5-4-6
0 0 0
(*** System Wide Parameter ***)
SECONDS
This menu programs how long the panel will delay reporting
Burglary alarm reports. Only burglary (non-re) zones that have
been programmed for Delay Report in MENU 3-1-7 — Report
Option will follow the Burglary Report Delay time.
1) Press [MENU] + [5] + [4] + [6]. The keypad will display the
current burglary report delay time.
Burg Report Delay
000 seconds
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new report delay time then
press [OK] to save and exit or press [MENU] to exit without
saving. Valid entires are 0 to 255 seconds
Comms > Dialler Reporting >
Fire Report Delay
MENU 5-4-7
0 0 0
(*** System Wide Parameter ***)
SECONDS
This menu programs how long the panel will delay reporting re
zone alarm reports. Only re zones that have been programmed
for Delay Report in MENU 3-1-7 — Report Option will follow the
Fire Report Delay time.
1) Press [MENU] + [5] + [4] + [7]. The keypad will display the
current Fire Report Delay time.
Fire Report Delay
000 seconds
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new report delay time then
press [OK] to save and exit or press [MENU] to exit without
saving. Valid entires are 0 to 255 seconds.
COMM S R EGI STR AT IO N
Comms > Registration >
Customer
MENU 5-5-0
Reserved for future use.
Comms > Registration >
Installer
MENU 5-5-1
Reserved for future use.
Comms > Comms Test >
Email Address
-
MENU 5-5-8
This menu allows the master user to program an email address
that the system will send email reports to. A maximum of 80
characters can be used to program the email address.
1) Enter your Master PIN + [MENU].
2) Enter [5] + [5] + [8] + [OK].
The keypad will display the current email address.
Email P001
_
Press
OK to SAVE
3) Use the numeric, [0] to [9], [] and [] keys to enter or change
the email address as required.
At any time you can use the [] and [] keys to scroll
through the complete list of available characters.
To clear all characters from the cursor position to the
right, press the [OFF] key.
4) When the email address is complete, press [OK] to save and exit,
or press [MENU] to exit without saving.
To stop email reporting simply remove the email
address or disable all of the email options in MENU
5-5-9.
When entering an email address the @ symbol is
represented on the keypad display as .
To enter this character press the 1 key repeatedly until
the symbol appears in the display.
Comms > MyAlarm >
Email Options
-
MENU 5-5-9
1 Open / Close Reports Y
2 Zone Alarm Reports Y
3 Zone Trouble Reports Y
4 System Reports Y
5 Access Reports Y
6 Reserved N
7 Reserved N
8 Reserved N