5-8
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Access Programming
Access > Global Properties >
PIN Retry Count
MENU 1-5-1
(*** System Wide Parameter ***)
6
This menu sets how many times an invalid PIN can be
entered before the keypad will be quarantined or locked out.
See MENU 6-1-8 — Keypad Lockout Time to set the lockout time
period.
An Access Denied report will be sent to the base station when
the keypad is quanrantined. If keypad lockout is not required
set this option to 0.
The PIN retry count is reset every time the corresponding area is
turned All On, Part On or O.
1) Enter [MENU] + [1] + [5] + [1]. The keypad will display the
current PIN retry count.
PIN Retry Count
06
Press 0-9 OK to SAVE
2) Enter the required PIN Retry Count using the up and down
arrow keys then press [OK] to save and exit or press [MENU] to
exit without saving. Valid entries are 1 - 15 , 0 = Unlimited.
Access > Global Properties >
Installer PIN
MENU 1-5-2
(*** System Wide Parameter ***)
1 2 3 4
This menu sets the Installer PIN. The Installer can access all
menu functions and can also disarm one or multiple areas. The
Installer PIN Can Be Up To 8 Digits Long.
The factory default Installer PIN is 1234.
1) Enter [MENU] + [1] + [5] + [2]. The keypad will display the
current Installer PIN.
Installer PIN
12340000
Press 0-9 OK to SAVE
2) Enter the required PIN Retry Count using the up and down
arrow keys then press [OK] to save and exit or press [MENU] to
exit without saving.
Access > Global Properties >
PIN Expire Time
MENU 1-5-3
0 3 0
(*** System Wide Parameter ***)
DAYS
This menu programs how many days PINs that have been
programmed to expire, will be able to operate the system.
Every time a valid temporary code is used, the Expire Time
counter will restart.
To renew a temporary user, the Installer or Master user
must reprogram the PIN. The PIN Expire Time is global for all
temporary PIN users.
1) Enter [MENU] + [1] + [5] + [3]. The keypad will display the
current PIN Expire Time.
PIN Expire Time
030 Days
Press 0-9 OK to SAVE
2) Enter the new PIN Expire Time using the numeric keys.
Valid entries are 0 - 255 days.
3) Press [OK] to save and exit or press [MENU] to exit without
saving. cursor position to the end of the line.
PROX R EAD ERS
Access > Prox Reader >
Name
MENU 1-6-0
R e a d e r 1 N a m e
This menu allows you to program the name or location
description of the prox reader. Up to 8 dierent Readers can
be used on the Solution 16
plus
via keypads that have built-in
Readers.
1) Enter [MENU] + [1] + [6] + [0] and select the Reader from the list
and press [OK].
Name R001
Reader 1 Name
Press 0 0-9 OK to SAVE
2) Use the arrow and number keys to move and change text.
When the Reader Name is complete, press [OK]. At any time
you can press the [OFF] key to clear the text from the current
cursor position to the end of the line.
See Alpha Text Programming in Section 4 - Programming
Overview for further detail on entering alpha text.
Access > Prox Reader >
Area Assignment
MENU 1-6-1
1
This menu programs which area (1 to 4) the Reader will operate. Each
reader can only be assigned to operate a single area.
When using a prox keypad reader, if you set the area assignment to
a specic area number then only that area will arm / disarm when a
valid token is used.
If you set the area assignment to 0 (zero), and a token is presented
then the keypad will move to the rst area which that user has
access to. If the same token is presented a second time then the area
currenttly in focus will arm or disarm.
If the user wants to arm / disarm a dierent area which they have