9-10
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Comms Programming
It is important to realise that this code is only used to start the
connection process. Once a connection is established, the voice
module will ask the user to enter their PIN before they will be
able to control the panel. The Voice Access Code is shared by all
users who need this type of access to the panel. See the CM100
documention for more details.
1) Press [MENU] + [5] + [3] + [6]. The keypad will display the
current DTMF options.
Voice Access Code N001
9#
Press 0-9 OK to SAVE
2) Using the numeric keys enter the new Voice Access Code then
press [OK] to save and exit or press [MENU] to exit without
saving.
Comms > Remiote Access >
CLI Number
MENU 5-3-7
First
Number
1 Digits 32
Second
Number
1 Digits 32
Third
Number
1 Digits 32
CLI Numbers (Call Line Identication) allows the Solution control
panel to answer an incoming call only when the control panel
identies that the incoming call is from any one of the three
CLI numbers programmed. Up to three dierent CLI telephone
numbers can be programmed, each having a maximum of 32
digits.
1) Enter [MENU] + [5] + [3] + [7]. The keypad will display
information for CLI number 1.
CLI Telephone Number 1
Press  0-9 OK to SAVE
2) Using the numeric keys, enter all the digits for CLI number 1.
You can change a single digit by scrolling the cursor left or
right. For special characters including, pause, * or #, use the
up and down arrow keys.
3) Press [OK] to program CLI number 2.
CLI Telephone Number 2
Press  0-9 OK to SAVE
4) Using the numeric keys, enter all the digits for CLI number 2 .
5) Press [OK] to program CLI number 3.
6) When nished Press [OK] to save and exit or press [MENU] to
exit without saving.
i
Note
Up to 3 Phone numbers can be entered for CLI Call Line
Identication for remote access detection. You must enter STD
code plus the compete number for this option to work. Press [OK]
after each telephone number is entered to save and move to the
next number.
REP ORT ING O P TI O NS
Comms > Dialler Reporting >
TX Format Dest 1
MENU 5-4-0
0 = Disable 1
1 = Contact ID 7 = Domestic
2 = SIA 8 = Voice 13 = Reserved
3 = Serial STU 9 = SIA+ 14 = SMS - No Parity
4 = GSM 10 = Reserved 15 = Reserved
5 = WEB MAIL 11 = Reserved
6 = SMS 12 = Reserved
This menu allows you to program the transmission format or
language the panel will use to send event reports to Destination
1. The panel has two separate destinations that reports can be
sent to and each one can be set to use a dierent transmission
format depending on the application.
At factory default, all reports are routed to Destination 1.
1) Press [MENU] + [5] + [4] + [0]. The keypad will display the
current Transmission Format for Destination 1.
TX Format Dest 1 P001
01 - Contact ID
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Transmission
Format required then Press [OK] to save and exit or press
[MENU] to exit without saving.
i
Note
Option 14 - SMS - No Parity, is only available in version 1.02 or
higher.
Comms > Dialler Reporting >
TX Format Dest 2
MENU 5-4-1
0 = Disable 1
1 = Contact ID 7 = Domestic
2 = SIA 8 = Voice 13 = Reserved
3 = Serial STU 9 = SIA + 14 = SMS - No Parity
4 = GSM 10 = Reserved 15 = Reserved
5 = WEB MAIL 11 = Reserved
6 = SMS 12 = Reserved
This menu allows you to program the transmission format or
language the panel will use to send event reports to Destination
2.
1) Press [MENU] + [5] + [4] + [1]. The keypad will display the
current Transmission Format for Destination 2.

Table of Contents