Safety
1.13 Dangers after switching off the machine
Residual dangers:
- Caution when working on the pneumatics. (there may
still be pressure even after venting).
- Caution when working on the hydraulics. (there may
still be pressure although the pump is out of action).
- Caution when working on the electrical installation.
(the supply line is still live even after switching off the
main switch).
1.14 Reversal of the working motion in case of emergency!
* Select manual mode, (see separate programming
instructions),
* Push the „lift die“ button. (the die will move upwards).
Residual dangers are particularly
electrical voltages that are still present
even after EMERGENCY-OFF or switching
off the main switch (see section 1.7.2).