EasyManua.ls Logo

Brocade Communications Systems MLX Series - Page 45

Brocade Communications Systems MLX Series
452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 27
53-1002373-02
Router modules
1
8x10GE-X interface modules
The 8x10GE-X interface modules provide 8 ports of 10 Gigabit Ethernet with support for 1M IPv4
routes in hardware.
NOTE
Gen-2 8x10GE-X modules require high speed switch fabric modules to operate. You can replace
switch fabric modules with high-speed switch fabric modules while the system is powered on and
running. For more information about high-speed switch fabric modules, refer to “High-speed switch
fabric modules” on page 50.
Figure 16 shows the faceplate of the 8x10GE-X module.
FIGURE 16 8x10GE-X module faceplate
8x10GE-X modules support SFP+ optics only; they do not support SFP or CFP optics. For a list of
supported SFP+ optics, refer to the latest version of the Brocade Optics Family Data Sheet,
available online in the following location:
http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p
df
MLXe-16 six four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
for 3+3 redundancy, install four 1800W PSU
seven to eight a minimum of five 1200W PSU
for 4+4 redundancy, install eight 1800W PSU
for 5+3 redundancy, install eight 1200W PSU
Brocade NetIron
XMR 1600
eight (1x100GE) four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
MLXe-32 twelve four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
thirteen to sixteen five 2400W PSU
for 5+3 redundancy, install eight 2400W PSU
four 3000W PSU
for 4x4 redundancy, instal eight 3000W PSU
Brocade NetIron
XMR 3200
sixteen (1x100GE) four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
TABLE 6 Power supply requirements for 100xGbE modules (Continued)
Router type Number of 100xGbE
modules installed
Power supply requirements (minimum required-redundancy requirements)
1
2
7
8

Table of Contents

Other manuals for Brocade Communications Systems MLX Series