3-67
Confidential
(11) Release the Hook to remove the Fuser drive gear Z25 from the Process drive unit.
(12) Release the Hook to open the Paper feed motor FFC holder. Release the Paper feed
motor flat cable from the securing fixtures. Release the Lock to disconnect the Paper feed
motor flat cable from the Paper feed motor.
Fig. 3-58
Harness routing: Refer to “6. Process drive unit”.
Paper feed motor
Hook
Hook
Fuser drive gear Z25
Paper feed motor FFC holder
Process drive unit
Paper feed motor flat cable
Lock