5-9
Confidential
< Operating Procedure >
For models with touch panel
(1) Press the [1], and then the [0] in the initial state of maintenance mode. “WSW00” is 
displayed on the LCD.
(2) Enter the worker switch number that you want to change the setting.
The following display appears on the LCD.
(3) Press the [◄] or [►] to move the cursor to the desired selector, and change the setting by 
pressing the [1] or [0].
(4) When changing the setting is completed, press the [SET]. The new selector setting value 
is stored in the EEPROM, and the LCD returns to the ready state for worker switch 
number entry (“WSW00”).
(5) When all switch setting is completed, press the [X] to return the machine to the initial state 
of maintenance mode.
For models without touch panel
(1) Press the [▲] or [▼] in the initial state of maintenance mode to display 
“MAINTENANCE 10” on the LCD, and press the [OK]. “WSW00” is displayed on the 
LCD. The LCD enters into the ready state for worker switch number entry.
(2) Press the [▲] or [▼] to display the worker switch number that you want to change the 
setting on the LCD.
(3) Press the [OK]. The following display appears on the LCD.
(4) Pressing the [▲] enters “1” and pressing the [▼] enters “0”. Press the button of the 
number that you want to enter to Selector No.1. The underline cursor moves to the next 
digit.
(5) Use the [▲] or [▼] to keep entering numbers until the Selector No.8 is entered in the 
procedures from (2) to (5).
(6) After entering the Selector No.8, press the [OK]. The new selector setting value is stored 
in the EEPROM, and the LCD returns to the ready state for worker switch number entry 
(“WSW00”).
(7) When all switch setting is completed, press the [Cancel] to return the machine to the initial 
state of maintenance mode.
 Selector No.1 Selector No.8
 Selector No.1 Selector No.8