2-41
Confidential
Print Unable 
02
Turn the power off 
and then back on 
again.
Cannot detect the synchronized 
signal of the paper feed motor. 
The speed of the paper feed 
motor does not stabilize within 
the specified time.
0201 2-48
Cannot detect the synchronized 
signal of the process motor. The 
speed of the process motor 
does not stabilize within the 
specified time.
0202 2-48
Print Unable 
05
Turn the power off 
and then back on 
again.
Detected the fuser unit 
temperature error.
0501 2-49
0502 2-49
0503 2-49
0504 2-49
0505 2-49
0506 2-49
050A 2-50
050B 2-50
050C 2-50
Print Unable 
08
Turn the power off 
and then back on 
again.
An error occurred in the internal 
temperature sensor.
0800 2-50
Print Unable 
09
Turn the power off 
and then back on 
again.
Detected irregular power supply 
for more than 100 times.
0900 2-51
Print Unable 
0A
Turn the power off 
and then back on 
again.
Main PCB detected the fan 
failure.
0A02 2-51
Print Unable 
0B
Turn the power off 
and then back on 
again.
An error occurred in the high-
voltage power supply PCB while 
operating.
0B01 2-52
An error occurred in the high-
voltage power supply PCB 
when the machine was in the 
ready state.
0B02 2-52
Print Unable 
0C
Turn the power off 
and then back on 
again.
An error occurred in the density 
sensor.
0C00 2-52
Print Unable 
0E
Turn the power off 
and then back on 
again.
An error occurred during the 
high-voltage power supply PCB 
ID check.
0E00 2-52
Error message
Description
Error 
codes
Refer 
to:
First line Second line