Loading...
T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
12- 8 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electric drive motor – 1760
Installation instructions for external temperature sensor
Fasten the metallic lacquer and the sensor with masking tape and
allow it to harden.
Remove the masking tape. The temperature sensor should now be
fixed in place and covered entirely by metallic lacquer.
Remove the ferrite block from the old sensor and mount it on the ca-
ble to the new sensor.
Remove the contact from the broken sensor, which is attached to
the motor.
Place the new sensor contact in the old bracket and connect it to the
cabling.
Fasten the old contact and its cabling using a cable tie so it cannot
damage anything.